Article title

The Wavenumber Algorithm for Full-Matrix Imaging Using an Ultrasonic Array

Type
D - Journal article
Title of journal
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL
Article number
-
Volume number
55
Issue number
11
First page of article
2450
ISSN of journal
0885-3010
Year of publication
2008
Number of additional authors
2
Additional information

Ultrasonic array imaging is widely used in industry for non-destructive testing (NDT). Paper describes frequency-domain imaging technique that is significantly faster than traditional delay-and-sum, time-domain techniques. Work was performed in collaboration with Rolls-Royce as part of MoD-funded project (£662k, 2004-11) on nuclear submarine NDT. Paper is in top 2% of most-cited in journal within REF period (Web of Science 4/11/2013).