For the current REF see the REF 2021 website REF 2021 logo

Output details

13 - Electrical and Electronic Engineering, Metallurgy and Materials

University of Southampton

Return to search Previous output Next output
Output 325 of 326 in the submission
Article title

Zero phase filtering for lightning impulse evaluation: a K-factor filter for the revision of IEC60060-1 and-2

Type
D - Journal article
Title of journal
IEEE Transactions on Power Delivery
Article number
-
Volume number
23
Issue number
1
First page of article
3
ISSN of journal
0885-8977
Year of publication
2008
Number of additional authors
3
Additional information

Significance of output:

This research has had significant impact as the developed method described has now been adopted by the International Electrotechnical Commission into its standard IEC60060-1 and is now the “informative approach” for applying the ‘k-factor’ when determining lightning impulse parameters. The standard ensures that high voltage lightning impulse measurements worldwide use the same analytical methodology when determining the rise time, peak voltage and time to decay to 50% of the peak value.