Article title

Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

Type
D - Journal article
Title of journal
Journal of Instrumentation
Article number
T12002
Volume number
4
Issue number
December
First page of article
-
ISSN of journal
1748-0221
Year of publication
2010
URL
-
Number of additional authors
30
Additional information

The paper describes characterisation and verification of the critical front-end module for the Planck Satellite, an international telescope developed by the European Space Agency and NASA. Here the low noise amplifier at the heart of the radiometer plus switching components exhibit noise performance between 3 and 5 times the quantum limit in the frequency band between 30 and 44 GHz. This banded radiometer was subsequently adopted by the international system verification programme team. (Contact Lead Planck Scientist at Jet Propulsion laboratories, NASA, contact details available). [NOTE: Author George published under maiden name Kettle]