Article title

Statistical analysis of the AC breakdown voltages of ester based transformer oils

Type
D - Journal article
Title of journal
IEEE Transactions on Dielectrics and Electrical Insulation
Article number
-
Volume number
15
Issue number
4
First page of article
1044
ISSN of journal
1558-4135
Year of publication
2008
URL
-
Number of additional authors
1
Additional information

This paper analyses the statistics of breakdown voltages of environmentally friendly esters. Funded by a consortium of companies including National Grid, UKPN, Scottish Power (contact details available) it aims to increase the knowledge of liquids alternative to mineral oil and ester application in large power transformers. It has led to further funding, £420k and £1,050k for second and third phases of research in transformer insulation systems, sponsored by National Grid, Scottish Power, UKPN and others. This work has been further developed by Alstom Grid (DOI: 10.1109/TDEI.2012.6311494), Delft University of Technology(DOI: 10.1109/CEIDP.2012.6378927), and University of Leicester (DOI: 10.1109/TDEI.2012.6311509).

Interdisciplinary
-
Cross-referral requested
-
Research group
5 - Electrical Energy and Power Systems
Proposed double-weighted
No
Double-weighted statement
-
Reserve for a double-weighted output
No
Non-English
No
English abstract
-