An FPGA Implementation of Frequency Output

Type
D - Journal article
Title of journal
IEEE Transactions on Industrial Electronics
Article number
-
Volume number
56
Issue number
3
First page of article
648
ISSN of journal
0278-0046
Year of publication
2009
URL
-
Number of additional authors
2
Additional information

A technique for generating low frequency (<10kHz) pulse trains to very high precision (error < 10-5 % over 1s interval), using low cost hardware suitable for industrial measurement. It has been implemented in Invensys’ CFT-50/1 Coriolis meters to improve the dynamic response to step changes in the process flow rate. In the downstream oil industry, mechanical flowmeters (turbine, PD) have fast dynamic responses but also high maintenance requirements. Replacing them with low maintenance electronic instruments such as Coriolis meters requires an equivalent dynamic response to pass meter proving standards. This is now being achieved. (http://www.Invensys.com/en, contact details available).