For the current REF see the REF 2021 website REF 2021 logo

Output details

15 - General Engineering

Brunel University London

Return to search Previous output Next output
Output 247 of 258 in the submission
Article title

Time reconstruction and performance of the CMS electromagnetic calorimeter

Type
D - Journal article
Title of journal
Journal of Instrumentation
Article number
T03011
Volume number
5
Issue number
03
First page of article
-
ISSN of journal
1748-0221
Year of publication
2010
Number of additional authors
2425
Additional information

The electromagnetic calorimeter (ECAL) sits at the heart of the CMS detector the LHC. It uses a dense scintillator whose light is detected with fast silicon and vacuum photodetectors. As the detector of high-energy electrons and photons it plays a key role in most CMS physics results, including the Higgs boson discovery paper (Physics Letters B 716 30-61 2012) This paper summarises the design, construction and key operational parameters (0.5% energy resolution, 100ps timing), of the ECAL. I played a major STFC supported role (PP/E000479/1, ST/K001639/1) in the design, testing and monitoring of the industrially produced radiation-tolerant vacuum photodetectors.

Interdisciplinary
-
Cross-referral requested
-
Research group
None
Proposed double-weighted
No
Double-weighted statement
-
Reserve for a double-weighted output
No
Non-English
No